VMIC100-VMMIC100-VMDIC100.

Hyfire > Rivelazione incendio analogico indirizzata > Moduli > VMIC100-VMMIC100-VMDIC100.

[av_heading tag=’h3′ padding=’10’ heading=’VMIC100-VMMIC100-VMDIC100 – Moduli ad 1 ingresso e 1 uscita supervisionati’ color=” style=’blockquote modern-quote’ custom_font=” size=’25’ subheading_active=” subheading_size=’15’ custom_class=” admin_preview_bg=” av-desktop-hide=” av-medium-hide=” av-small-hide=” av-mini-hide=” av-medium-font-size-title=” av-small-font-size-title=” av-mini-font-size-title=” av-medium-font-size=” av-small-font-size=” av-mini-font-size=”][/av_heading]

[av_three_fifth first min_height=” vertical_alignment=” space=” custom_margin=” margin=’0px’ padding=’0px’ border=” border_color=” radius=’0px’ background_color=” src=” background_position=’top left’ background_repeat=’no-repeat’ animation=” mobile_breaking=” mobile_display=”]

[av_hr class=’invisible’ height=’20’ shadow=’no-shadow’ position=’center’ custom_border=’av-border-thin’ custom_width=’50px’ custom_border_color=” custom_margin_top=’30px’ custom_margin_bottom=’30px’ icon_select=’yes’ custom_icon_color=” icon=’ue808′ font=’entypo-fontello’ admin_preview_bg=”]

[av_tab_container position=’top_tab’ boxed=’border_tabs’ initial=’1′]
[av_tab title=’Caratteristiche’ icon_select=’yes’ icon=’ue856′ font=’entypo-fontello’]
Isolatori di corto circuito in ogni dispositivo.
Protezione OEM con codice personalizzato.
Istruzione operative mediante simboli standard.
Informazione sulla qualità della connessione.
Indirizzabile mediante apposito dispositivo. (VPU1000) o, se previsto, da centrale.
Diagnostica interna.
Linea di uscita controllata per interruzione e/o corto circuito.
[/av_tab]
[av_tab title=’Generalità’ icon_select=’yes’ icon=’ue810′ font=’entypo-fontello’]
Modulo di ingresso uscita, alimentato dal loop.
Il canale di ingresso è supervisionato mediante resistenza di fine linea. Permette la connessione al loop di contatti normalmente aperti o dispositivi di supervisione. attivare relè di scambio con contatti liberi da potenziale
Il canale di uscita costituito da un relè, normalmente rilasciato, è attivato con comando da centrale di gestione
L’alimentazione da fornire al dispositivo di segnalazione è controllata.
Due LED bicolore comandati da centrale indicano lo stato del modulo (attivo, guasto).

I moduli di ingresso-uscita sono disponibili in diversi contenitori:
VMIC100 Modulo ingresso uscita montaggio da parete
VMMIC100 Modulo ingresso uscita – minimodulo
VMDIC100 Modulo ingresso uscita montaggio guida DIN .

Certificazioni:

EN 54-18:2005 + AC:2007 Fire detection and fire alarm systems. Input/output devices
EN 54-17:2005 + AC:2007 Fire detection and fire alarm systems. Short-circuit isolators
CPR – VE0710CPR20130701
[/av_tab]
[av_tab title=’Download’ icon_select=’yes’ icon=’ue82d’ font=’entypo-fontello’]

[/av_tab]
[/av_tab_container]

[/av_three_fifth][av_two_fifth min_height=” vertical_alignment=” space=” custom_margin=” margin=’0px’ padding=’0px’ border=” border_color=” radius=’0px’ background_color=” src=” background_position=’top left’ background_repeat=’no-repeat’ animation=” mobile_breaking=” mobile_display=”]
[av_hr class=’invisible’ height=’50’ shadow=’no-shadow’ position=’center’ custom_border=’av-border-thin’ custom_width=’50px’ custom_border_color=” custom_margin_top=’30px’ custom_margin_bottom=’30px’ icon_select=’yes’ custom_icon_color=” icon=’ue808′ font=’entypo-fontello’ admin_preview_bg=”]

[av_image_hotspot src=’https://www.ibitfireline.com/wp-content/uploads/2018/02/VMIC100-300×300.jpg’ attachment=’646′ attachment_size=’medium’ animation=’no-animation’ hotspot_layout=’numbered’ hotspot_tooltip_display=” hotspot_mobile=’aviaTBhotspot_mobile’]
[/av_two_fifth]

[av_one_full first min_height=” vertical_alignment=” space=” custom_margin=” margin=’0px’ padding=’0px’ border=” border_color=” radius=’0px’ background_color=” src=” background_position=’top left’ background_repeat=’no-repeat’ animation=” mobile_breaking=” mobile_display=”]
[av_hr class=’invisible’ height=’30’ shadow=’no-shadow’ position=’center’ custom_border=’av-border-thin’ custom_width=’50px’ custom_border_color=” custom_margin_top=’30px’ custom_margin_bottom=’30px’ icon_select=’yes’ custom_icon_color=” icon=’ue808′ font=’entypo-fontello’ admin_preview_bg=”]

[av_table purpose=’tabular’ pricing_table_design=’avia_pricing_default’ pricing_hidden_cells=” caption=” responsive_styling=’avia_responsive_table’]
[av_row row_style=”][av_cell col_style=”]Caratteristiche tecniche[/av_cell][av_cell col_style=”][/av_cell][/av_row]
[av_row row_style=”][av_cell col_style=”]Tensione operativa[/av_cell][av_cell col_style=”]Alimentato dalla tensione del loop[/av_cell][/av_row]
[av_row row_style=”][av_cell col_style=”]Corrente assorbita[/av_cell][av_cell col_style=”]120uA@24V (comunicazione normale)[/av_cell][/av_row]
[av_row row_style=”][av_cell col_style=”]Corrente LED (in allarme)[/av_cell][av_cell col_style=”]6mA[/av_cell][/av_row]
[av_row row_style=”][av_cell col_style=”]Classe di protezione[/av_cell][av_cell col_style=”]IP42[/av_cell][/av_row]
[av_row row_style=”][av_cell col_style=”]Temperatura di funzionamento[/av_cell][av_cell col_style=”]-20°C – +55°C[/av_cell][/av_row]
[av_row row_style=”][av_cell col_style=”]Umidità relativa[/av_cell][av_cell col_style=”]5% – 95% senza condensa[/av_cell][/av_row]
[av_row row_style=”][av_cell col_style=”]Resistenza di fine linea[/av_cell][av_cell col_style=”]Rfl=27Kohm[/av_cell][/av_row]
[av_row row_style=”][av_cell col_style=”]Resistenza di allarme[/av_cell][av_cell col_style=”]Ra=10Kohm[/av_cell][/av_row]
[/av_table]
[/av_one_full]

%d blogger hanno fatto clic su Mi Piace per questo: